Diagnostics, ] diagnostics, ] tests – Flintec FT-13 User Manual

Page 43: ] serial numbers, ] printing parameter values

Advertising
background image

FT-13 Technical Manual, Rev. 1.40 March 2013

Page 43 of 56

9. D

IAGNOSTICS

The parameter block [9--] contains certain functions for checking and testing.

[9--] Diagnostics

The operations about checking and testing the instrument can be made here.

[90-] Tests

[900 ] Key Pad test

In this step each

key‟s ASCII code will be shown on the display as you press the related key. By this way

you can test if all the keys are functioning or not. Pressing “ ” key will take you to the next parameter.

[901 ] Serial Interface-1 test

The characters in the alphabet will sequentially be transferred from serial interface-1 by pressing the
“Zero” key repeatedly. Received numerical data is shown on display.

[902 ] Digital Input test

[ı X YY]
To perform a digital input test, enter the number of the input to YY

digits via “Tare” and “Zero” keys and

press the “Enter” key. “X” shows the logical condition of this input.

[903 ] Digital Output test

[o X YY]
To perform a digital output test, enter the number of the output to YY digits and press <Enter>. “X” shows
the logical condition of that output which can be changed by pressing the <Zero> key.

[904 ] mV Indication

When pressing the <Enter> key the output voltage of the load cell will be shown on the display. This
uncalibrated value is only for test- and service purposes.

[91-] Serial Numbers

[910]

Instrument Serial No.

[911]

Option 1 Serial No.

[912]

Option 2 Serial No.

[913]

Option 3 Serial No

When pressing the <Enter> key the serial number of the instrument or the option will be shown.

[914]

Application Software Revision No. of legal for trade related part

When pressing the <Enter> key the MID revision no. of the application software will be shown.

[915]

Application Software Revision No. of non-legal for trade related part

When pressing the <Enter> key the revision no. of the application software will be shown.

Note: The revision no. of the application software is also shown at the power up of the instrument
(Format: A XX.YY.)

[99-] Printing Parameter Values

[990] Print All Parameters

By pressing the <Print> key all parameters can be printed.

[991] Loading Default Parameters

When pressing the <Enter> key the [ Ld dEf ] message appears on the display. Press the <Tare> key for
loading the default values or press the <F> key to go to “9-“ sub block.

Advertising