FT-13 Technical Manual, Rev. 1.40 March 2013

Page 35 of 56

The RS485 interface termination can be done by short circuiting pin no. 19 and 20 (panel type enclosure) or by jumper JP4
on the interface board (stainless steel housing). These short circuits terminate the line with an internal 100 Ω resistor.

20 mA CL ASCII interface connection:

The 20mA CL ASCII output is disabled by
default. For enabling this output the
connections should be made as given in figure
shown on the left.
(Enabled output is not available for 12 V DC
instruments and stainless steel housings).

8.2.3 Continuous Output Mode

The continuous output mode allows for a fast and continuous data export to connected peripheral devices. The
output data structure is described in Appendix 2.

8.2.4 Host Mode

The indicator can communicate with a PC in host mode. You can upload or download data to the indicator by
adjusting the related interface parameters within the FLINTEC IndFace software.

8.2.5 Print Mode

The print mode is not available for more than one interface.

Data output after filling cycle

The data are transmitted automatically in filling mode or by pressing the <Print> key in weighing mode.

Example:

10/01/2007 10:57 Cn= 169 G= 1999kg T= 0kg N= 1999kg

D A T E

T IM E

C N

G R O S S

T A R E

N E T

M
S
D

L
S
D

S
P

M
S
D

L
S
D

S
P

M
S
D

L
S
D

S
P

M
S
D

L
S
D

S
P

M
S
D

L
S
D

S
P

M
S
D

L
S
D

L
F

C
R

1 0

1

5

7

7

2

1 1

4

1 1

2

1 1

1

1

Total Report

Press the <F> key and the <Σ> key sequentially. While the total weight is shown on the display, press the
<Print> key to print out the total report in the format shown below. To clear the total and the statistics press the
<1> key after the message [ CLr 1 ] is shown on the display.

Start

: Start time of the first filling / discharging cycle

End

: End time of the last filling / discharging cycle

N

: Number of filling / discharging cycles

Total

: Total weight of filling / discharging

If the filling / discharging weight is controlled, the exact filling or
discharging weight is added to the “Total” value. If the filling /
discharging weight is not controlled, the target value is added to
the “Total” value.

Batch Report

Press the <F> key and the <Σ> key sequentially. While the total weight is shown on display, press the <Enter>
key. The message [StAtiS] will be shown on the display. Then press the <Print> key to print out the batch report
in the format shown below. To clear the total and the statistics press the <1> key after the message [ CLr 1 ] is
shown on the display.

TOTAL REPORT

Start : dd.mm.yyyy mm:hh
End : dd.mm.yyyy mm:hh
N

= xxxxxx

Total = xxxxxx kg

Advertising