Appendix 7: parameter’s default table, Ppendix, Arameter – Flintec FT-13 User Manual

Page 54: Efault, Able

Advertising
background image

FT-13 Technical Manual, Rev. 1.40 March 2013

Page 54 of 56

A

PPENDIX

7:

P

ARAMETER

S

D

EFAULT

T

ABLE

Parameter

Factory defaults

0-- Interface
00- Serial Interface 1

0 Data format

2 = Printer

1 Baud rate

3 = 9600

2 Handshake

0 = Disable

3 Address

0

4 Data length and parity

0 = 8 bit, no parity

5 Checksum

1 = Enable

02- Serial Interface 2

20 Data format

0 = Disable

21 Baud rate

3 = 9600

22 Handshake

0 = Disable

23 Address

0

24 Mode

0 = RS232C

25 Data length and parity

0 = 8 bit, no parity

03- Ethernet / Profibus

30 Ethernet data format

0 = Disable

31 Ethernet address

0

32 Profibus data format

0 = 32-bit integer

33 Profibus address

0

34 CANopen data format

0 = 32-bit integer

35 CANopen address

0

36 ProfiNet data format

0 = 32-bit integer

04- Printer

41 Date + Time

0 = don‟t print

1-- Configuration
12- Filter

120 Filter

6

14- Entries

140 Date entry

dd.mm.yy

141 Time entry

hh.mm

2-- Scale Parameters
20- Set up

200 Approved

0 = No

201 Increased indication

0 = With x10 key

203 Zero with key

1 = ± %2

204 Auto Zero Tracking

1 = ± 0.1e

205 Tare

1 = With Tare Key

206 Motion detector

1 = ± 0,5e

21- Scale Build

212 Capacity (2) / d(2)

6 kg / 0.001 kg

3-- Calibration / Adjustment
30- Calibration

301 Calibration

31- Adjustment

310 Zero adjustment
311 Span adjustment
312 Span adjustment under load

Parameter

Factory defaults

5-- Filling
50-

Filling Parameters

51-

500 Filling programme

Programme 0

501 Preact correction factor

30%

502 Preact correction frequency 1
503 Preact correction limit

100%

504 Coarse feed. control delay

0.7 s

505 Fine feeding control delay

0.7 s

506 Maximum settling time

1.0 s (delay 0.0 s)

507 Jogging time

0.0 s

508 Filling time

0 = Disable

509 Maximum weight

3000

50A Start / Reset keys

0 = Disable

50b Filling Quantity control

0

50C Filling type

1

50d Fine feeding time at start

0 (=starts with coarse f.)

50E Zeroing period

250 s

50F Zeroing delay

3.0 s

510 Indication in filling process

0 (= increasing)

59- Filling Performance Test

590 Coarse feed test
591 Fine feed test

8-- Metrological Data
80- Legal Metrology

800 Calibration counter

9-- Diagnostics
90- Tests

900 Key Pad test
901 Serial interface 1 test
902 Digital input test
903 Digital output test
904 mV indication

91- Serial numbers

910 FT-13 serial no.
911 Option 1 serial no.
912 Option 2 serial no.
913 Option 3 serial no.
914 A XX.--
915 A --.YY

99- Print Parameters

990 All parameters
991 Load default parameters