7.7 Error Messages

Error Message

Description

The “Tare range” error message appears if the tare of the
container is not between the minimum and maximum tare
values defined in the process parameters. If the error is not
present anymore it can be acknowledged by a reset. Valid
for programme 0, 1 and 2.

This message appears if tareing is not possible, e.g. if the
weight is negative or the scale is not stable. It is shown
alternately to the weight value. When the conditions become
normal, the error is acknowledged by the start input in fillling
or the discharge input in discharging..
Valid for programme 0, 1, 2, 4 and 5.

This means the weight is out of the zero range at the
beginning of the filling cycle. It can be acknowledged by the
start input. Valid for programme 3, 6 and 8.

This message appears if zeroing cannot be done at the
beginning of the filling, e.g. the weight can be higher than the
zeroing range or not stable. It is shown alternately to the
weight value. This error is canceled by the reset input.
Valid for programme 3, 4, 6, 7 and 8

At the end of filling, if the weight is out of the filling tolerances,
this message appears. It is shown alternately to the weight
value. The error is acknowledged by the start input.
Valid for programme 0, 1, 2, 3, 4, 5, 6, 7 and 8

It shows the filling period is extended. The filling valves are
closed. The error is acknowledged by the reset input.
Valid for programme 0, 1, 2, 3, 4, 5, 6, 7 and 8

It shows the weight value is higher than the “Maximum
weight” limit (parameter [509]). The filling gate is closed. It
disappears when the weight becomes smaller than the
“Maximum weight” limit.
Valid for programme 0, 1, 2, 3, 4, 5, 6, 7 and 8

If the sum of the target value and the tare value is higher than
the “Maximum weight” limit (parameter [509]), this message
appears. It is acknowledged by the reset input.
Valid for programme 0, 1, 2, 3, 4, 5, 6, 7 and 8

This message is shown if the “Valve down” input deactivates
during the filling process and the filling valves ares closed.
The filling continues if the “Valve down” input activates again.
Valid for programme 1 and 2

While the filling valve is going down, if the weight value is
higher than “SAFEty” weight, this message is shown.
It waits for reset.
Valid for programme 1 and 2

Gate position error.
Valid for programme 3, 4, 5, 6 and 8.

The total weight value is higher than [t_trGT].
Clear the total weigt for starting the process again.
Valid for programme 6.

Clamp position error.
Valid for programme 7.

E CLMP

E ZEro

XXXXX

t ovEr

E GAtE

E hoLE

E vALv

E trGt

E ovEr

FıLL t

E toL

XXXXX

E ZrnG

XXXXX

XXXXX

E tArE

XXXXX

E trnG