FT-13 Technical Manual, Rev. 1.40 March 2013

Page 22 of 56

Process Parameters

Description

+

+

+

When FT-

13 is in the “Ready” status (the top LED in the LED

bar is “on” ) press the keys shown on the left sequentially.

This is the delay time at the end of emptying. The bottom
gate is opened and emtying starts. When the weight goes
into zero range, “ d_dıSC “ delay starts and the gate is closed
at the end of this period. The delay time can be entered by
the keypad up to 9.9 s.

If the gate position control is enabled and after the start input
is activated, the gate position will be checked at the end of
this period. It can be entered by the keypad up to 25.0 s.

Emptying type.
If it is set to “1“, the weight is followed during emptying. When
the weight goes into the zero range, the “d_dıSC” delay starts
and the gate is closed at the end of this delay. If it is set to “0“
only the “d-dıSC” delay is enabled and the gate is left open
during the “d_dıSC” period.

Gate position check

0 = No

1 = Yes

Zero range.
If the weight is in this range, it means the scale is empty. To
start the filling the weight has to be in the zero range.

Exit

Process Messages

Description

It is displayed during the automatic zeroing.

It is displayed during “Gate position control”.

This is displayed at the end of the filling. It is shown
alternately to the weight value. It disappears when emtying
starts.

Discharge delay time enabled.

- ZEro -

FULL

XXXXX

d_dıSC

X.X

d_GAtE

X.X

E_tYPE

X

ZEro_r

XXXXX

GAtE

d dEL

GAT_Ch
k

X