7.3.7 Programme 6: Filling and Emptying Type 2

F T -1 3

F T -1 3

Application:

Bagging machines

Material feeding systems

The filling stops if the total weight is higher than

the entered total limit value

Operation:

The tank/hopper is filled up to the target value

accurately by 2-speed or 3-speed filling.

The discharge input starts the complete emtying

of the tank/hopper and the weight is totalized.

Filling and emptying must be in sequence.

If the actual total weight is higher than the total

target value, the filling does not start.


For non-legal for trade discontinuous totalizer
applications, use the fine feed output for charging
and the parameters should be entered as:

Target = Tolerance

Coarse = Fine = 0

[501]=00

Process Parameters

Description

+

+

+

When type FT-

13 is in the “Ready” status (the top LED in

the LED bar is “on” ) press the keys shown on the left
sequentially.

This is the delay time at the end of emptying. The bottom
gate is opened and emtying starts. When the weight goes
into the zero range, “ d_dıSC “ delay starts and the gate is
closed at the end of this period. The delay time can be
entered by the keypad up to 9.9 s.

If the gate position control is enabled and after the start
input> is activated, the gate position will be checked at the
end of this period.
It can be entered by the keypad up to 25.0 s.

Emptying type.
If it is set to “1“, the weight is followed during emptying.
Wh

en the weight goes into the zero range, the “d_dıSC”

delay starts and the gate is closed at the end of this delay.
If it is set to “0“, only the “d-dıSC” delay is enabled and the
gate is left open during the “d_dıSC” period.

Gate position check

0 = No

1 = “Gate position control” is enabled

This is the requested total weight. If the totalized weight is
higher than the requested total weight, the filling does not
start and the process ends. The value is entered in “kg”
without floating point. Enter “0” to disable the total check.

Zero range.
If the weigh is in this range, it means the scale is empty. To
start filling the weight has to be in the zero range.

Exit

t_trGT

XXXXX

d_dıSC

X.X

d_GAtE

X.X

E_tYPE

X

ZEro_r

XXXXX

GAT_Ch
k

X