Appendix 2: continues output mode data structure, Ppendix, Ontinues – Flintec FT-13 User Manual

Page 45: Utput, Tructure

Advertising
background image

FT-13 Technical Manual, Rev. 1.40 March 2013

Page 45 of 56

A

PPENDIX

2:

C

ONTINUES

O

UTPUT

M

ODE

D

ATA

S

TRUCTURE

The format and the definition of the continuous data output is given below.

Status

Indicated

Tare

STX STA STB STC D5

D4

D3

D2

D1

D0

D5

D4

D3

D2

D1

D0

CR

CSUM


The definition of the status bytes STA, STB and STC is given below.

Definition Table for Status Byte A

Bits 0, 1 and 2

Bits 3 and 4

Bit 5

Bit 6

Bit 7

0

1

2

Decimal point

3

4

Increment size

Always 1

Always 1

X

0

0

0

XXXXOO

1

0

X 1

1

0

0

XXXXXO

0

1

X 2

0

1

0

XXXXXX

1

1

X 5

1

1

0

XXXXX.X

0

0

1

XXXX.XX

1

0

1

XXX.XXX

0

1

1

XX.XXXX

1

1

1

X.XXXXX

Definition Table for Status Byte B

Bit 0

Gross = 0

Net=1

Bit 1

Weight positive = 0

Weight negative=1

Bit 2

Overload = 1

Bit 3

Stable = 0

Unstable =1

Bit 4

Always = 1

Bit 5

Always = 1

Bit 6

Always = 0

Bit 7

x

Definition Table for Status Byte C

Bit 0

Always 0

Bit 1

Always 0

Bit 2

Always 0

Bit 3

Always 0

Bit 4

Always 1

Bit 5

Always 1

Bit 6

Always 0

Bit 7

x


STX = 0x02
CR = 0x0D
CSUM = 0

– (STX + STATUS A + … + CR)