REMOVING AND REPLACING
BOBBIN CASE
• Raise presser foot.
•
Turn hand wheel toward you until
needle is in its highest position.
• Open slide plate with downward finger
pressure.
Draw
plate
toward
you,
opening it all the way to raise the
needle plate locking pin.
• Remove needle plate.
• Remove bobbin.
• To remove bobbin case:
Turn bobbin case holder to back as far
as it will go. Lift out bobbin case.
• To replace bobbin case:
Guide the forked end under the feed
and then draw the bobbin case under
the position plate as illustrated. Turn
bobbin case holder all the way for
ward to lock bobbin case In position.
After locking the bobbin case in posi
tion, check that the bobbin case does
not bind but has slight rotational
movement.
• Replace bobbin.
• Replace needle plate.
• Close slide plate to lower needle plate
locking pin and secure needle plate.