Input signal (10MHz REF In BNC)

100 mVPP to 5 VPP(square
or sine)

Input impedance (10MHz REF In BNC)

50 Ω ±5 Ω

Input signal (PXI_CLK10_IN on fifth slot)

5 V or 3.3 V TTL signal

100 MHz System Reference Clock: PXIe_CLK100
Maximum slot-to-slot skew

100 ps

Accuracy

±25 ppm

Cooling
Fans

2 sets of 185.9 CFM fans

Per-slot cooling capacity

30 W (verified by 55°C
chamber test)

Physical
Slots

9
(1 x system slot, 1 x system
timing slot, 7 x hybrid
peripheral slots)

Dimensions

321.9 (W) x 191.4 (H) x 465.3
(D) mm (12.7 x 7.5 x 18 in.)

Weight

8.8 kg (19.4 lb)

Environmental
Storage

Ambient temperature: -20 to

70°C
Relative humidity: 10 to 90%,
noncondensing

Operating

Ambient temperature: 0 to

55°C
Relative humidity10 to 90%,
noncondensing

Functional shock

30 G, half-sine, 11 ms pulse
duration

Random Vibration

Operating: 5 to 500 Hz, 0.31
Grms, 3 axes
Nonoperating: 5 to 500 Hz,
2.46 Grms, 3 axes

Certification
Safety

EN 61010-1

Electromagnetic Compatibility

Emissions: EN 55011 Class A
Immunity: EN 61326-1

General Specifications