4
Introduction
Input signal (10MHz REF In BNC)
100 mVPP to 5 VPP(square
or sine)
Input impedance (10MHz REF In BNC)
50 Ω ±5 Ω
Input signal (PXI_CLK10_IN on fifth slot)
5 V or 3.3 V TTL signal
100 MHz System Reference Clock: PXIe_CLK100
Maximum slot-to-slot skew
100 ps
Accuracy
±25 ppm
Cooling
Fans
2 sets of 185.9 CFM fans
Per-slot cooling capacity
30 W (verified by 55°C
chamber test)
Physical
Slots
9
(1 x system slot, 1 x system
timing slot, 7 x hybrid
peripheral slots)
Dimensions
321.9 (W) x 191.4 (H) x 465.3
(D) mm (12.7 x 7.5 x 18 in.)
Weight
8.8 kg (19.4 lb)
Environmental
Storage
Ambient temperature: -20 to
70°C
Relative humidity: 10 to 90%,
noncondensing
Operating
Ambient temperature: 0 to
55°C
Relative humidity10 to 90%,
noncondensing
Functional shock
30 G, half-sine, 11 ms pulse
duration
Random Vibration
Operating: 5 to 500 Hz, 0.31
Grms, 3 axes
Nonoperating: 5 to 500 Hz,
2.46 Grms, 3 axes
Certification
Safety
EN 61010-1
Electromagnetic Compatibility
Emissions: EN 55011 Class A
Immunity: EN 61326-1