Monitoring/Control

Functions

*Write to Default Threshold (command 0xC0)

Writes to Default Threshold.

Use the SMB write word to write this command:

With default thresholds as follows:

*Reset MCU (command 0xC2)

Resets the MCU.

Use the SMB write word to write this command

SMB

Dir

Offset

Value

Description

Write word

>

0

SA

Slave address

>

1

0xC0

Command code

>

2

0-255

N/A

>

3

0-255

N/A

Default Thresholds

Target Chassis Temperature

50

5V Alarm Threshold

+-5%

3.3V Alarm Threshold

+-5%

+12V Alarm Threshold

+-5%

-12V Alarm Threshold

+-5%

Fan Speed Alarm Threshold

800

Temperature Alarm Threshold

70