Monitoring/Control Functions
53
PXES-2590
Use the SMB write word to write this word data:
Data format is as follows::
*Write Temperature Alarm Threshold (command 0xBE)
Writes the Temperature Alarm Threshold.
Use the SMB write word to write this word data:
Data format is as follows:
SMB
Dir
Offset
Value
Description
Write word
>
0
SA
Slave address
>
1
0xBC
Command code
>
2
0-255
Low byte data
>
3
0-255
High byte data
Bit
Description
15..0
Fan Speed Alarm Threshold. Unsigned 16-bit data,
the LSB is 1rpm. If any of the fan speed is lower
than this threshold, the MCU triggers a fan speed
alarm. The threshold range is between 1 and 10000
SMB
Dir
Offset
Value
Description
Write word
>
0
SA
Slave address
>
1
0xBE
Command code
>
2
0-255
Low byte data
>
3
0-255
High byte data
Bit
Description
7..0
Temperature Alarm Threshold. Unsigned 8-bit data, the
LSB is 1°C. If MCU detects any of the backplane
temperature (Temperature 0~7) is higher than the
threshold, the MCU triggers a temperature alarm. The
threshold range is between 0 and 110
15..8
Reserved.