Figure 3-2, Target temperature parameters and legend – ADLINK PXES-2590 User Manual

Page 41

Advertising
background image

System Management

31

PXES-2590

Figure 3-2: Target Temperature Parameters and Legend

Target Temp can be set by entering the desired target temper-

ature value in the field and clicking Set.

Temperature

Event

A

0°C

Lowest chassis temperature at which fan
speeds commence ramping up for final 25°
temperature mark (see Item E)

B

45°

Highest chassis temperature at which fan
speeds commence ramping up for final 70°
temperature mark (see Item C)

C

70°

Highest maximum chassis temperature at
which the fans reach maximum speed

D

25°C to 70°C

(45 degree range)

Range over which maximum chassis
temperature (at which fans reach maximum
speed) can be set

E

25°C

Lowest maximum chassis temperature at
which fans reach maximum speed

5

10

25

20

15

30

35

40

45

50

55

60

65

70

0

0

100

40

Highest temperature (°C) reported by the 8 backplane sensors

Fan
voltage
duty
cycle
(%)

A

B

C

D

E

Advertising