4 monitoring/control functions, 1 smbus api, 2 function overview – ADLINK PXES-2590 User Manual

Page 43: Smbus api, Function overview, 4monitoring/control functions

Advertising
background image

Monitoring/Control Functions

33

PXES-2590

4

Monitoring/Control Functions

The monitoring/control function library can be used to create a

customized program for monitoring and controlling the PXES-
2590. The smbus interface on the system controller provides
access to system monitoring functions, including:

X

Read backplane/chassis data such as power/temperature/
fan speed

X

Set thresholds for power/temperature/fan

X

Read firmware version

X

Set fan speeds

The following abbreviations are used in this chapter:

4.1 SMBus API

The PXES-2590 SMBus slave address of the system monitoring

function is 0xC6h.

4.2 Function Overview

The following table shows all commands to access monitored data

MA Master

Address

MCU

Microcontroller on backplane.

SA

Slave Address (= 0x32)

SC

System controller located in slot 1

SMB

System Management Bus

Command

Function

Access

0x02

Read Alarm Status

R

0x04

Read 5V Voltage

R

0x06

Read 3.3V Voltage

R

0x08

Read +12V Voltage

R

0x0A

Read -12V Voltage

R

0x0C

Read 5Vsb Voltage

R

0x10

Read Temperature 1

R

0x12

Read Temperature 2

R

0x14

Read Temperature 3

R