Data format is as follows:

*Read Temperature 3 (command 0x14)

Reads the Temperature 3 Reading.

Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data:

Data format is as follows:

Receive Byte

>

4

SA

Slave address

<

5

0-255

High byte data

Bit

Description

15..0

Temperature 3. 16-bit data, 2’s complement, LSB is

0.1°C

SMB

Dir

Offset

Value

Description

Send Byte

>

0

SA

Slave address

>

1

0x16

Command code

Receive Byte

>

2

SA

Slave address

<

3

0-255

Low byte data

Receive Byte

>

4

SA

Slave address

<

5

0-255

High byte data

Bit

Description

15..0

Temperature 4. 16-bit data, 2’s complement, LSB is

0.1°C

SMB

Dir

Offset

Value

Description