Monitoring/Control Functions

49

PXES-2590

*Write Target Chassis Temperature (command 0xB0)

Writes the Target Chassis Temperature.

Use the SMB write word to write this word data

Data format is as follows:

*Write 5V Alarm Threshold (command 0xB2)

Writes the 5V Alarm Threshold.

Use the SMB write word to write this word data:

SMB

Dir

Offset

Value

Description

Write word

>

0

SA

Slave address

>

1

0xB0

Command code

>

2

0-255

Low byte data

>

3

0-255

High byte data

Bit

Description

7..0

Target chassis temperature setting. Unsigned 8-bit data,
the LSB is 1°C. The CPU can set the temperature at which
maximum fan speed is achieved. The system monitoring
MCU adjusts the fan speed according to this setting. The
threshold range is between 25 and 70

15..8

Reserved.

SMB

Dir

Offset

Value

Description

Write word

>

0

SA

Slave address

>

1

0xB2

Command code

>

2

0-255

Low byte data

>

3

0-255

High byte data