Monitoring/Control Functions

37

PXES-2590

*Read +12V Voltage (command 0x08)

Reads the +12V Voltage

Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data:

Data format is as follows:

*Read -12V Voltage (command 0x0A)

Reads the -12V Voltage

Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data:

Data format is as follows:

Send Byte

>

0

SA

Slave address

>

1

0x08

command code

Receive Byte

>

2

SA

Slave address

<

3

0-255

Low byte data

Receive Byte

>

4

SA

Slave address

<

5

0-255

High byte data

Bit

Description

15..0

+12V Voltage. Measured +12V voltage. 16-bit 2’s
complement , the LSB is 1mV

SMB

Dir

Offset

Value

Description

Send Byte

>

0

SA

Slave address

>

1

0x0A

Command code

Receive Byte

>

2

SA

Slave address

<

3

0-255

Low byte data

Receive Byte

>

4

SA

Slave address

<

5

0-255

High byte data

Bit

Description

15..0

-12V Voltage. Measured -12V voltage. 16-bit 2’s
complement, the LSB is 1mV