Monitoring/Control Functions
37
PXES-2590
*Read +12V Voltage (command 0x08)
Reads the +12V Voltage
Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data:
Data format is as follows:
*Read -12V Voltage (command 0x0A)
Reads the -12V Voltage
Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data:
Data format is as follows:
Send Byte
>
0
SA
Slave address
>
1
0x08
command code
Receive Byte
>
2
SA
Slave address
<
3
0-255
Low byte data
Receive Byte
>
4
SA
Slave address
<
5
0-255
High byte data
Bit
Description
15..0
+12V Voltage. Measured +12V voltage. 16-bit 2’s
complement , the LSB is 1mV
SMB
Dir
Offset
Value
Description
Send Byte
>
0
SA
Slave address
>
1
0x0A
Command code
Receive Byte
>
2
SA
Slave address
<
3
0-255
Low byte data
Receive Byte
>
4
SA
Slave address
<
5
0-255
High byte data
Bit
Description
15..0
-12V Voltage. Measured -12V voltage. 16-bit 2’s
complement, the LSB is 1mV