ADLINK PXES-2590 User Manual
Page 51
Monitoring/Control Functions
41
PXES-2590
*Read Temperature 4 (command 0x16)
Reads the Temperature 4 Reading.
Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data:
Data format is as follows:
*Read Temperature 5 (command 0x18)
Reads the Temperature 5 Reading.
Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data:
Data format is as follows:
SMB
Dir
Offset
Value
Description
Send Byte
>
0
SA
Slave address
>
1
0x16
command code
Receive Byte
>
2
SA
Slave address
<
3
0-255
Low byte data
Receive Byte
>
4
SA
Slave address
<
5
0-255
High byte data
Bit
Description
15..0
Temperature 4. 16-bit data, 2’s complement, LSB is
0.1°C
SMB
Dir
Offset
Value
Description
Send Byte
>
0
SA
Slave address
>
1
0x18
Command code
Receive Byte
>
2
SA
Slave address
<
3
0-255
Low byte data
Receive Byte
>
4
SA
Slave address
<
5
0-255
High byte data
Bit
Description
15..0
Temperature 5. 16-bit data, 2’s complement, LSB is
0.1°C