ADLINK PXES-2590 User Manual
Page 57
Advertising
![background image](/manuals/733421/57/background.png)
Monitoring/Control Functions
47
PXES-2590
*Block Read Chassis Data Part 2 (command 0x47)
Block reads the Chassis Data Structure Part 2.
Use the SMB Block Read to Read this data structure.
Data Format Description:
The whole Chassis Data Structure is as
typedef struct st_BlockRead
{
INT16 P_5V;
INT16 P_3V3;
INT16 P_5Vsb;
INT16 P_12V;
INT16 P_N12V;
INT16 T1;
INT16 T2;
INT16 T3;
INT16 T4;
INT16 T5;
UINT16 F1;
UINT16 F2;
UINT16 F3;
UINT16 MCU_Version;
UINT16 FAN_Mode;
UINT16 Max_Chassis_Temp;
UINT16 Threshold_5V;
UINT16 Threshold_3V3;
UINT16 Threshold_12V;
NOTE:
NOTE:
Use command 0x46 first, then command 0x47 to acquire the
entire data structure.
Advertising