Monitoring/Control Functions

39

PXES-2590

Data format is as follows:

*Read Temperature 2 (command 0x12)

Reads the Temperature 2 Reading.

Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data:

Data format is as follows:

*Read Temperature 3 (command 0x12)

Reads the Temperature 3 Reading.

Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data:

Bit

Description

15..0

5Vsb Voltage. Measured 5V standby voltage. 16-bit
2’s complement, the LSB is 1mV °C

SMB

Dir

Offset

Value

Description

Send Byte

>

0

SA

Slave address

>

1

0x12

command code

Receive Byte

>

2

SA

Slave address

<

3

0-255

Low byte data

Receive Byte

>

4

SA

Slave address

<

5

0-255

High byte data

Bit

Description

15..0

Temperature 2. 16-bit data, 2’s complement, LSB is

0.1°C

SMB

Dir

Offset

Value

Description

Send Byte

>

0

SA

Slave address

>

1

0x14

command code

Receive Byte

>

2

SA

Slave address

<

3

0-255

Low byte data

Advertising