39
PXES-2590
Data format is as follows:
*Read Temperature 2 (command 0x12)
Reads the Temperature 2 Reading.
Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data:
Data format is as follows:
*Read Temperature 3 (command 0x12)
Reads the Temperature 3 Reading.
Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data:
Bit
Description
15..0
5Vsb Voltage. Measured 5V standby voltage. 16-bit
2’s complement, the LSB is 1mV °C
SMB
Dir
Offset
Value
Description
Send Byte
>
0
SA
Slave address
>
1
0x12
command code
Receive Byte
>
2
SA
Slave address
<
3
0-255
Low byte data
Receive Byte
>
4
SA
Slave address
<
5
0-255
High byte data
Bit
Description
15..0
Temperature 2. 16-bit data, 2’s complement, LSB is
0.1°C
SMB
Dir
Offset
Value
Description
Send Byte
>
0
SA
Slave address
>
1
0x14
command code
Receive Byte
>
2
SA
Slave address
<
3
0-255
Low byte data