Monitoring/Control

Functions

Data format is as follows:

*Write 3.3V Alarm Threshold (command 0xB4)

Writes the 3.3V Alarm Threshold.

Use the SMB write word to write this word data:

Data format is as follows:

7..0

5V Under Voltage Alarm Threshold. Unsigned 8-bit data,
the LSB is 0.1%. If the 5V voltage falls below the
threshold, the MCU triggers a voltage alarm. For
example, if the under voltage threshold is set to 5%,
when the 5V is lower than 5V*0.95 (4.75V), the MCU
triggers voltage alarm. The threshold range is between 0
and 250

15..8

5V Over Voltage Alarm Threshold. Unsigned 8-bit data,
the LSB is 0.1%. If the 5V voltage is higher than this
threshold, the MCU triggers a voltage alarm. For
example, if the over voltage threshold is set to 5%, when
the 5V is higher than 5V*1.05 (5.25V), the MCU triggers
voltage alarm. The threshold range is between 0 and 250

SMB

Dir

Offset

Value

Description

Write word

>

0

SA

Slave address

>

1

0xB4

Command code

>

2

0-255

Low byte data

>

3

0-255

High byte data

Bit

Description

7..0

3.3V Under Voltage Alarm Threshold. Unsigned 8-bit
data, the LSB is 0.1%. If the 3.3V voltage is lower than
this threshold, the MCU triggers a voltage alarm. The
threshold range is between 0 and 250

15..8

3.3V Over Voltage Alarm Threshold. Unsigned 8-bit data,
the LSB is 0.1%. If the 3.3V voltage is higher than this
threshold, the MCU triggers a voltage alarm. The
threshold range is between 0 and 250