3 function library, Function library, Table 4-1: pxes-2590 functions – ADLINK PXES-2590 User Manual

Page 44

Advertising
background image

34

Monitoring/Control

Functions

Table 4-1: PXES-2590 Functions

4.3 Function Library

*Read Alarm Status (command 0x02)

Reads alarm status from the monitoring unit

Use the SMB 1 Send Byte and 2 Receive Byte to read this
word data:

0x16

Read Temperature 4

R

0x18

Read Temperature 5

R

0x20

Read Fan Speed 1

R

0x22

Read Fan Speed 2

R

0x24

Read Fan Speed 3

R

0x26

Read MCU code version

R

0x30

Read Target Chassis Temperature

R

0x44

Read Fan Speed Mode

R

0x46

Block Read Chassis Data Part 1

BR

0x47

Block Read Chassis Data Part 2

BR

0xB0

Write Target Chassis Temperature

W

0xB2

Write 5V Alarm Threshold

W

0xB4

Write 3.3V Alarm Threshold

W

0xB6

Write +12V Alarm Threshold

W

0xB8

Write -12V Alarm Threshold

W

0xBA

Write 5Vsb Alarm Threshold

W

0xBC

Write Fan Speed Alarm Threshold

W

0xBE

Write Temperature Alarm Threshold

W

0xC0

Write to Default Threshold

W

0xC2

Reset MCU

W

0xC4

Write Fan Speed Mode

W

SMB

Dir

Offset

Value

Description

Send Byte

>

0

SA

Slave address

>

1

0x02

command code

Command

Function

Access

Advertising