3 function library, Function library, Table 4-1: pxes-2590 functions – ADLINK PXES-2590 User Manual
Page 44
![background image](/manuals/733421/44/background.png)
34
Monitoring/Control
Functions
Table 4-1: PXES-2590 Functions
4.3 Function Library
*Read Alarm Status (command 0x02)
Reads alarm status from the monitoring unit
Use the SMB 1 Send Byte and 2 Receive Byte to read this
word data:
0x16
Read Temperature 4
R
0x18
Read Temperature 5
R
0x20
Read Fan Speed 1
R
0x22
Read Fan Speed 2
R
0x24
Read Fan Speed 3
R
0x26
Read MCU code version
R
0x30
Read Target Chassis Temperature
R
0x44
Read Fan Speed Mode
R
0x46
Block Read Chassis Data Part 1
BR
0x47
Block Read Chassis Data Part 2
BR
0xB0
Write Target Chassis Temperature
W
0xB2
Write 5V Alarm Threshold
W
0xB4
Write 3.3V Alarm Threshold
W
0xB6
Write +12V Alarm Threshold
W
0xB8
Write -12V Alarm Threshold
W
0xBA
Write 5Vsb Alarm Threshold
W
0xBC
Write Fan Speed Alarm Threshold
W
0xBE
Write Temperature Alarm Threshold
W
0xC0
Write to Default Threshold
W
0xC2
Reset MCU
W
0xC4
Write Fan Speed Mode
W
SMB
Dir
Offset
Value
Description
Send Byte
>
0
SA
Slave address
>
1
0x02
command code
Command
Function
Access