ADLINK PXES-2590 User Manual

Page 61

Advertising
background image

Monitoring/Control Functions

51

PXES-2590

*Write +12V Alarm Threshold (command 0xB6)

Writes the +12V Alarm Threshold.

Use the SMB write word to write this word data

Data format is as follows:

*Write -12V Alarm Threshold (command 0xB8)

Writes the -12V Alarm Threshold.

Use the SMB write word to write this word data

SMB

Dir

Offset

Value

Description

Write word

>

0

SA

Slave address

>

1

0xB6

Command code

>

2

0-255

Low byte data

>

3

0-255

High byte data

Bit

Description

7..0

+12V Under Voltage Alarm Threshold. Unsigned 8-
bit data, the LSB is 0.1%. If the +12V voltage is lower
than this threshold, the MCU triggers a voltage
alarm. The threshold range is between 0 and 250

15..8

+12V Over Voltage Alarm Threshold. Unsigned 8-bit
data, the LSB is 0.1%. If the +12V voltage is higher
than this threshold, the MCU triggers a voltage
alarm. The threshold range is between 0 and 250

SMB

Dir

Offset

Value

Description

Write word

>

0

SA

Slave address

>

1

0xB8

Command code

>

2

0-255

Low byte data

>

3

0-255

High byte data