Table 3-4: cpcis-3300bls chassis slots – ADLINK cPCI-6S10 User Manual

Page 33

Advertising
background image

Hardware Platform Management

23

cPCI-6S10

Message Interfaces

X

Access through Linux driver (on LMP locally): ipmitool
<command>

X

RMCP remote client: ipmitool -I lan -H <hostname> [-p
<port>] [-U <username>] [-A <authtype>] <command>

X

If bridged command is issued. An extra parameter should
be applied.

Z

-t: select target slave address (0xB0 for slot1, 0xB2 for
slot2, etc, in ADLINK Chassis cPCIS-3300BLS).

Table 3-4: cPCIS-3300BLS Chassis Slots

Examples

Access from local LMP

ipmitool mc info

Get device Information from onboard payload with Linux IPMI
driver.

ipmitool raw 0x06 0x01

Get device id with IPMI raw command.

Access from RMCP remote client, bridged through the BMC

Slot No.

IPMB Address (hex)

Type

01

B0

CPU

02

B2

CPU

03

B4

CPU

04

B6

CPU

05

B8

SWH

06

BA

CPU

07

BC

CPU

08

BE

CPU

09

C0

CPU

10

C4

SWH

11

C6

CPU

12

C8

CPU

13

CA

CPU

14

CC

CPU

Advertising