ADLINK cPCI-6S10 User Manual

Page 68

Advertising
background image

58

Hardware Platform Management

Example:

Get SDR use raw command.

List all SDR from IPMC (from Device SDR)

Request Fields

root@BCNMB-A:~# ipmitool -I lan -H 127.0.0.1 -U

admin -P admin raw 0xa 0x22

06 00

root@BCNMB-A:~# ipmitool -I lan -H 127.0.0.1 -U

admin -P admin raw 0xa 0x23 0x6 0x0 0 0 0

10

01 00 00 00 51 12 13 20 00 cc 29 00

root@BCNMB-A:~# ipmitool -I lan -H 172.20.5.225

-U admin -P admin -t 0xB4 sdr list all

BMC_WatchDog | 0 unspecified | nc

POWER_GOOD | 0 unspecified | cr

P1V | 1.01 Volts | ok

P1V2 | 1.20 Volts | ok

P1V5 | 1.50 Volts | ok

P0V75 | 0.74 Volts | ok

+3.3V | 3.32 Volts | ok

+5.0V | 5.05 Volts | ok

54685_TEMP | 34 degrees C | ok

56150_TEMP | 47 degrees C | ok

1

Reservation ID. LS Byte. Only required for partial reads with a non-
zero ‘Offset into record’ field. Use 0000h for reservation ID
otherwise.

2

Reservation ID. MS Byte.

3

Record ID of record to Get, LS Byte

4

Record ID of record to Get, MS Byte

5

Offset into record

6

Bytes to read. FFh means read entire record.