4 getting started, 1 heatsink, 2 installing the cpci-6s10 – ADLINK cPCI-6S10 User Manual

Page 75: 3 configuring the cpci-6s10, Serial port connection, Heatsink, Installing the cpci-6s10, Configuring the cpci-6s10, 4getting started

Advertising
background image

Getting Started

65

cPCI-6S10

4

Getting Started

This chapter describes the installation of the cPCI-6S10:

4.1

Heatsink

The cPCI-6S10 comes with on board BGA BCM 56150 processor
and heatsink pre-installed. Removal of heatsink/CPU by users is not
recommended. Please contact your ADLINK service representative
for assistance.

4.2

Installing the cPCI-6S10

Insert the cPCI-6S10 into a PICMG 2.16 backplane with a fabric
slot. The symbol for the switch slot is

4.3

Configuring the cPCI-6S10

There is a serial port and management port at the front panel of
the cPCI-6S10. Both ports can be used to connect to the
cPCI-6S10 console. Follow the steps below.

User's can connect to the cPCI-6S10 console using "PuTTY".
Download PuTTY from http
://www.putty.org. Run the program to
open the PuTTY configuration window.

Serial Port Connection

Connect the RJ-45 to DB-9 adapter cable to the COM port on the
front panel. Set "Serial line" to the COM port of the client PC.

CAUTION:

Handle with caution as the heat sink can get very hot. Do not
touch the heat sink when installing or removing the board. The
board should not be placed on any surface or in any form of
storage container until the board and heat sink have cooled
down to room temperature.