Hardware Platform Management

Example:

Show Card Version

Re-Scan GA Input

Example:

Use this command to read the Card’s IPMB address.

Request Data Fields

Response Data Fields

Report Geography Address

11

Predefined – 5Ah

[root@iProc /root]#ipmitool raw 0x30 0x12
a5 56 01 02 50 53 13 53 00 5a

ipmitool

ipmitool [parameters] raw 0x30 0x22

Terminal
mode

[C0 00 22]

Description Re-Scan the IPMB address from the HW GA Input

[root@iProc /root]#ipmitool raw 0x30 0x22
b8

1

None

1

Completion Code

2

IPMB Address – xxh

ipmitool

ipmitool [parameters] raw 0x30 0xF0

Terminal
mode

[C0 00 F0]

description Get 6S10 Geography Address.