Re-scan ga input – ADLINK cPCI-6S10 User Manual
Page 70
Advertising
60
Hardware Platform Management
Example:
Show Card Version
Re-Scan GA Input
Example:
Use this command to read the Card’s IPMB address.
Request Data Fields
Response Data Fields
Report Geography Address
11
Predefined – 5Ah
[root@iProc /root]#ipmitool raw 0x30 0x12
a5 56 01 02 50 53 13 53 00 5a
ipmitool
ipmitool [parameters] raw 0x30 0x22
Terminal
mode
[C0 00 22]
Description Re-Scan the IPMB address from the HW GA Input
[root@iProc /root]#ipmitool raw 0x30 0x22
b8
1
None
1
Completion Code
2
IPMB Address – xxh
ipmitool
ipmitool [parameters] raw 0x30 0xF0
Terminal
mode
[C0 00 F0]
description Get 6S10 Geography Address.