Figure 2.2, Regular drop box network connections, Figure 2.3 – LINK Systems LinkNet II User Manual

Page 13: Repeater drop box network connections

Advertising
background image

Figure 2.2: Regular Drop Box Network Connections

Figure 2.3: Repeater Drop Box Network Connections


All three connectors should be wired as follows:

GND

Green/White and White/Green

RXD+

Orange/White

RXD- White/Orange
TXD+

Blue/White

TXD- White/Blue
SHLD

Shield (bare) Wire of Cable


For Repeaters Only:

L1

“Hot” side of 110V AC

L2

“Neutral” side of 110V AC

M. GND Machine Ground

Some older versions of the drop box do not have the “SHLD” terminal. In this case, tie the shields of all
the cables together with a wire nut.

Whenever possible, the drop boxes should be mounted on the press in easy reach for troubleshooting

purposes. In addition, the length of the line from the drop box to the Link equipment should be kept as
short as reasonably possible. The drop boxes have knockouts sized for ½” conduit or cord grips.



Manual Version 1.1

10/28/2001

2.3