Microlink operator terminal network connections, 5 microlink, Operator – LINK Systems LinkNet II User Manual

Page 16: Terminal network connections, Figure 2.7, Microlink operator terminal (back view)

Advertising
background image

2.5 MicroLink Operator Terminal Network Connections

The communications ports for the MicroLink operator terminal are internal to the unit. The back

cover must be removed to access the ports. Figure 2.7 shows a view of the inside of the MicroLink
terminal. Note that ports 4 and 5 reside on an optional (but usually present) “piggyback” circuit board.
If for some reason this card is not present, contact Link for upgrade information and pricing.


Port 5 is the network port and should be wired as follows:


REF

Green/White and White/Green

RXD+

Orange/White

RXD- White/Orange
TXD+

Blue/White

TXD- White/Blue

Figure 2.7: MicroLink Operator Terminal (Back View)

Manual Version 1.1

10/28/2001