Network job storage on the microlink oit, Network job recall on the microlink oit – LINK Systems LinkNet II User Manual

Page 92

Advertising
background image

are sent by the MicroLink under certain conditions without operator intervention. In all cases,
automatically entered down time codes are automatically cleared when the press makes another stroke.

If the network is not running or if a wiring problem is preventing the MicroLink from

communicating with LinkNet, the message “* Network NOT on line! *” will be displayed in the current
down time code description area.

To select a down time code, use the up and down arrow keys to move the highlight to the desired

code and press the “Select” softkey. The down time code will then become the current code until
cleared or replaced. It is not necessary to clear a down time code before selecting a new one.

If a down time code is active, whether automatic or operator entered, a “Clear DTC” softkey will be

displayed. Hitting this softkey or hitting the “CLEAR” key on the regular keypad will clear the down
time code.


9.3 Network Job Storage on the MicroLink OIT

Virtually unlimited job storage is available when using a MicroLink with LinkNet. Jobs can be

stored from the MicroLink to LinkNet in the following manner:

• From the main menu of the MicroLink OIT, hit the “Job Setups” softkey to enter the jobs screen.

• Hit the “Store Job” softkey to enter the store screen. Note that the Run/Prog key MUST be in the

Prog position for this softkey to be available!


• Change the job number and job description, if desired. This step may be skipped if the job number

and job description as shown in this screen are already correct.


• Hit the “Store Network” softkey to send the job to the network. A status screen will appear to show

the progress of the job send. A message will appear indicating whether or not the store was
successful. If the network is not on line, a message will appear indicating this condition. A job
CANNOT be stored to the network unless it is online!

IMPORTANT: Jobs stored using the “Store Setup” softkey will still be stored as local
jobs on the MicroLink as they always have - NOT the network. A job stored on the
network is independent of the same job number stored at the MicroLink. If you change
the settings for a job on the network, it DOES NOT affect the settings of the same job
number stored on the MicroLink and vice versa! Make sure the job is sent to its intended
destination.



9.4 Network Job Recall on the MicroLink OIT

Jobs may be recalled from LinkNet to the MicroLink 5000 in the following manner:


• From the main menu of the MicroLink OIT, hit the “Job Setups” softkey to enter the jobs screen.

• Hit the “Recall Job” softkey to enter the recall screen. Note that the Run/Prog key MUST be in the

Prog position for this softkey to be available!


• Hit the “Recall Network” softkey to enter the network job recall screen.