AC Power Requirements

The AC input power requirements depend on the frequency and output power rating of the generator.
Table 11-II below, lists both the AC requirements (maximum current drawn before overload) and the AC
outlet service rating for each model.

Operating

Frequency

Generator

Model Number

Overload

Power

Ratings
(Watts)

Input AC Power Requirements

Nominal AC Volt

@ Maximum RMS Current

North America/

Japan

AC Outlet Rating

15kHz

15XX360-2X-XX

3600

200-240V 50/60 Hz @ 25 Amps

30 Amps

15kHz

15XX480-2X-XX

4800

200-240V 50/60 Hz @ 30 Amps

20kHz

20XX120-1X-XX

1200

100-120V 50/60 Hz @ 15 Amps

15 Amps

20kHz

20XX120-2X-XX

1200

200-240V 50/60 Hz @ 8 Amps

20kHz

20XX180-2X-XX

1800

200-240V 50/60 Hz @ 12 Amps

20kHz

20XX240-2X-XX

2400

200-240V 50/60 Hz @ 15 Amps

20kHz

20XX360-2X-XX

3600

200-240V 50/60 Hz @ 25 Amps

30 Amps

20kHz

20XX480-2X-XX

4800

200-240V 50/60 Hz @ 30 Amps

30kHz

30XX090-1X-XX

900

100-120V 50/60 Hz @ 8 Amps

15 Amps

30kHz

30XX090-2X-XX

900

200-240V 50/60 Hz @ 8 Amps

30kHz

30XX120-1X-XX

1200

100-120V 50/60 Hz @ 15 Amps

30kHz

30XX120-2X-XX

1200

200-240V 50/60 Hz @ 8 Amps

30kHz

30XX180-2X-XX

1800

200-240V 50/60 Hz @ 12 Amps

40kHz

40XX060-1X-XX

600

100-120V 50/60 Hz @ 8 Amps

40kHz

40XX060-2X-XX

600

200-240V 50/60 Hz @ 5 Amps

40kHz

40XX090-1X-XX

900

100-120V 50/60 Hz @ 15 Amps

40kHz

40XX090-2X-XX

900

200-240V 50/60 Hz @ 8 Amps

40kHz

40XX120-1X-XX

1200

100-120V 50/60 Hz @ 15 Amps

40kHz

40XX120-2X-XX

1200

200-240V 50/60 Hz @ 8 Amps

NOTES:

An X used above in the Model Numbers is a “wildcard” character meaning any valid character code combination.

Maximum line current requirement is specified at the minimum nominal AC line voltage and the rated power level.

Models rated for 200-240V nominal AC line voltage include an IEC power inlet to attach an international IEC (type)
power cord. (The 3600W and 4800W models include a 30A fixed power cord.)

A power cord with a domestic three wire grounding plug is included with each standard system (NEMA 6-15P).

Models rated for 200-240V nominal AC line are fully CE compliant for use in Europe or any other country in the
world.

Models rated for 200-240V nominal AC line require a 16 Amp or 30 Amp grounded AC outlet rating, outside of North
America/Japan.

Models rated for 100-120V nominal AC line are for use in North America or Japan and include a 15 A fixed power
cord.

The fixed power cord includes a three-wire grounding plug (NEMA 5-15P configuration). These models are fully FCC