Page  7

Section 10 - Options

Dukane Manual Part No. 403-574-01

Connecting Cables

For stand-alone interfaces and securely installed panel
mounted interfaces:

Rear Connections

Refer to Figure 10 -7 below, and complete these
connections.

1. Earth ground - Connect one end of a user-supplied

14-Gauge ground wire to the ground connection at
the rear of the MPC,

A

in Figure 10 -7. Connect the

other end of the wire to an earth ground potential at
the electrical box that supplies power to the equipment
(or to the equipment enclosure into which your system
is installed).

2. U/S (ultrasonic) cable (Dukane P/N 200-479-XX -

Order the correct cable length for your installation.)
- Connect one end of the cable to the left rear U/S con-
nector of the MPC interface,

B

in Figure 10 -7. The

other end of the cable connects to J1 of the ultrasonic
generator.

3. MPC Interface cable (Dukane P/N 200-1408-XX -

Order the correct cable length for your installation.)
- Connect one end of the cable to the right rear MPC
Interface connector,

C

in Figure 10 -7. The other

end of the cable connects to the MPC INTERFACE
connector on the ultrasonic generator.

Figure 10 - 7

MPC Interface Rear Connectors

C

A

B

Front Connections

Refer to Figure 10 -8 below.
Complete these connections.

1. Probe Cable(s) - Beginning with PROBE 1, con-

nect one end of the cable (See Table 10 - IV below.)
to the U/S connector on the MPC’s front panel,

D

in Figure 10 -7. Connect the other end of the cable
to the corresponding probe for your specific welding
application.

2. Repeat Step 1 for each of the remaining probes (in

sequence: 2, 3, 4, etc.) in your system.

Figure 10- 8

MPC Interface Front Connectors

D

System

Frequency

Probe P/N

Cable P/N :

MPC to Probe

20kHz

41C25

200-479-XX

41C27

30kHz

41A60R-129

200-615-XX

40kHz

41A40

Table 10- IV

Probe Cables