Page  37

Section 5 – Standard System Status and Controls

Dukane Manual Part No. 403-574-01

Front Panel Overview

This section provides an overview of the front panel’s two
main functions: monitoring (with the system displays), and
controlling the system (with the user navigation control
keys).

LOAD

80

60

100

OVER

40

0

20

SYSTEM POWER OUTPUT LEVEL

SYSTEM OPERATING MODE

ON

LINE

OFF

LINE

POWER

TEST

# 1 PART COUNT 125
WELD TIME 0.080 S
POWER 1050 W
ENERGY 350 J

INF

O

O

N

/O

FF

LIN

E

TE

ST

C

AN

CE

L

ENT

ER

Figure 5 - 1 Front Panel Monitoring Detail

System Power Output Level
Bar Graph

Overload Indicator

System Operating Mode

4-line LCD Display

System Displays

System Power Output Level
(Bar Graph)

A bar graph displays the percentage of ultrasonic power
being drawn by the load.
The display uses LED’s that show:

GREEN - normal operation.

YELLOW - warning of potential overload.

RED - warning that an overload condition exists.

Peak Detect Feature
To indicate the maximum peak power achieved during a
weld cycle, the LED in the bar graph corresponding to
the peak level remains on (for about one second) after the
weld cycle has been completed.

Flash on Overload at 90%
The

OVERLOAD

indicator begins to flash (RED) when

the generator produces 90% of the overload power rating.
This feature alerts the operator to an impending overload
fault condition.

Bar Graph Power Scaling
Power scaling is related to amplitude. At 100% amplitude
the whole graph is lit, and the generator is operating at
100% power. At 50% amplitude the entire graph is lit, and
the generator is operating at 50% power.
If the amplitude setting is lowered, the graph rescales
automatically according to the revised amplitude.
Example: With a 1200W generator, at 50% amplitude, if
the whole graph is lit, that represents 600W.

System Operating Mode

ON LINE - ONLINE

appears GREEN after AC power has

been activated and the generator is operating normally.

POWER TEST -

POWER TEST appears RED and will

flash for several seconds when AC power is first turned
on. The generator runs a self-test during the start-up
sequence.

OFFLINE - OFFLINE

appears YELLOW indicating that

the generator’s power output is disabled.

4-line LCD Display

This is where process control parameters can be set, and
where process results can be monitored.