Dukane ULTRASONIC GENERATOR/POWER SUPPLY LS 403-574-01 User Manual

Page 38

Advertising
background image

Page  33

Page  3 

iQ Series

,

Ultrasonic Generator/Power Supply LS User’s Manual

Section 4 – Standard Connections

Dukane Manual Part No. 403-574-01

Page  33

Page  3 

iQ Series

,

Ultrasonic Generator/Power Supply LS User’s Manual

Section 4 – Standard Connections

Ultrasound Output Connector

The ultrasound output connector used with all standard
generators is a high voltage (5000V) coaxial style
SHV-BNC connector. This connector provides superior
shielding of electrical noise, compared to other types of
connectors. The ultrasound output connector mates with
fully shielded coaxial ultrasound cables that are secured
with a simple and reliable quarter-turn bayonet style
attachment mechanism.

Figure 4 - 8 Ultrasound Output Connector

CAUTION

The ultrasonic output from
this connector (that drives the
attached ultrasonic load) is a
very high AC voltage. At high
power levels this can exceed
2 amperes of current and must
be securely terminated via
the ultrasound cable for safe
operation. Use original equip-
ment ultrasound cables for safe
and reliable system operation.
Improperly assembled ultra-
sound cables can result in high
voltage arcing and will destroy
the ultrasound connectors.

Do not use your generator
if there is any evidence of
arcing (black carbon depos-
its) on either the ultrasound
output connector or the ul-
trasound cable connectors.

Advertising