Page  51

Section 6 – Process Control Settings

Dukane Manual Part No. 403-574-01

HOW TO - Weld by Energy

(Available only if

generator has energy option.)

1. Press CANCEL until you see the Main Menu screen as

it is shown here.

Move the selection indicator to PROCESS SETUP.

2. Press ENTER and you will see the screen as shown

here.

3. Select PROCESS CONTROL, and press ENTER.

With no option boards installed in the generator, you will
get a WELD BY choice of iQ SYSTEM or

AUTOMATION.

4. Select iQ SYSTEM, and press ENTER.

5. Select WELD CONTROL.

6. Select WELD BY ENERGY.

7. Select the digits with the RIGHT and LEFT arrows. Use

the UP and DOWN arrows to select the value (energy ,
in Joules).

8. When done with the energy entry, press ENTER, and an

ENTRY ACCEPTED message will appear.

# 1:
OPERATE MODE
PROCESS SETUP
HARDWARE SETUP

PROCESS SETUP
PROCESS CONTROL
PROCESS LIMITS
UTILITIES

AUTOMATED PROBE
WELD CONTROL BY
iQ SYSTEM
AUTOMATION

WELD CONTROL
HOLD CONTROL
AFTERBURST CONTROL
AMPLITUDE CONTROL

WELD TIME
0.000 S
SELECT DIGIT
SELECT VALUE

WELD BY TIME
WELD BY PEAK POWER
WELD BY ENERGY

NOTE

In the above example Energy was the primary method
of weld control. Next, the energy of the weld was set (in
Joules). The program then asks the operator to choose
and set a MAX WELD TIME, a secondary characteristic
that also controls the weld. Select a time between 0 and 30
seconds. The time forces the weld portion of the cycle to
stop even if the energy parameter is not met. Press ENTER.
An ENTRY ACCEPTED message will appear.