iQ Series

,

Ultrasonic Generator/Power Supply LS User’s Manual

Dukane Manual Part No. 403-574-01

HOW TO - Adjust Amplitude

1. Press CANCEL until you see the Main Menu screen as

it is shown here.

Move the selection indicator to PROCESS SETUP.

2. Press ENTER and you will see the screen as shown

here.

3. Select PROCESS CONTROL, and press ENTER.

With no option boards installed in the generator, you will
get a WELD BY choice of iQ SYSTEM or

AUTOMATION.

4. Select iQ SYSTEM, and press ENTER.

5. Select AMPLITUDE CONTROL.

6. Select AMPLITUDE SETTING.

7. Adjust the amplitude. This is a value with a minimum

of 20% and a maximum of 100%.

Select the digits with the RIGHT and LEFT arrows. Use
the UP and DOWN arrows to select the value.

8. When done with the amplitude entry, press ENTER, and

an ENTRY ACCEPTED message will appear.

# 1:
OPERATE MODE
PROCESS SETUP
HARDWARE SETUP

PROCESS SETUP
PROCESS CONTROL
PROCESS LIMITS
UTILITIES

AUTOMATED PROBE
WELD CONTROL BY
iQ SYSTEM
AUTOMATION

WELD CONTROL
HOLD CONTROL
AFTERBURST CONTROL
AMPLITUDE CONTROL

AMPLITUDE CONTROL
AMPLITUDE SETTING
RAMP UP/ DOWN TIME


AMPLITUDE SETTING
90 %

CHANGE VALUE

SELECT DIGIT

NOTE

Once the amplitude is set and the entry
is accepted, the program takes you back
to the AMPLITUDE CONTROL screen.
From there you may adjust the RAMP
UP/DOWN times or go to some other part
of the menu.