Section 4 – Standard Connections

Figure 3 - 6 Generator - Rear View (low profile model)

Automation Controlled Probe
System

Step 1. Ground the generator chassis using the supplied

14-Gauge wire, and attach it to the grounding
stud:

A

in Figure 3 -6.

Step 2. Optional – Ground the probe support. This is a

user–supplied 14-Gauge wire.

Step 3. Input Cable - Attach the automation control

cable from the user–supplied automation equip-
ment to the system input HD-15 connector, J2
on the I/O panel:

B

in Figure 3 -6.

Step 4. Output Cable - Attach an output cable - DB25

type - from J3 to your equipment to monitor sys-
tem status.

Step 5. Attach the high voltage coaxial cable from the

probe to the ultrasound output connector J1:

C

in Figure 3 -6.

Step 6. Connect the AC power cord to the generator

IEC power inlet connector, and plug the other
end into an approved AC outlet:

D

in Figure 3 -6.

NOTE

Refer to Section 10, Options for information
about other features.

LINE VOLTAGE:
200-240 Vac
50/60Hz, 10A

PE

AC POWER

INLET

GROUNDING

STUD

J2

J3

J4

J7

J1









ULTRASOUND OUTPUT

INPUTS

OUTPUTS

J7 is optional.