Dukane ULTRASONIC GENERATOR/POWER SUPPLY LS 403-574-01 User Manual

Page 96

Advertising
background image

Page  0 

iQ Series

,

Ultrasonic Generator/Power Supply LS User’s Manual

Dukane Manual Part No. 403-574-01

J2

U/S

I

0

LINE VOLTAGE:
200-240 Vac
50/60Hz, 15A

PE

J3

J4

J1

BUS ERROR

PROFIBUS

J16

iQ LinQ

PROFIBUS Communications Module

Part Number - 110-4554

The

PROFIBUS

option module allows the iQ generator

to connect to a

PROFIBUS

network. Since

PROFIBUS

is multipoint instead of point-to-point, more than one
generator can be connected to a single bus cable. The

PROFIBUS

module offers access to generator parameter

settings and status information listed below. In addition,
if desired, all I/O wiring can be replaced with a single

PROFIBUS

cable.

Control Parameters available via PROFIBUS

1. Set weld method to Time, Energy, or Peak Power. Set

associated values in seconds, joules, or watts.

2. Set Amplitude, Ramp Up Time, and Ramp Down

Time.

3. Enable and set Trigger by Power parameters.

4. Enable and set Hold Time.

5. Enable and set Afterburst delay and duration.

6. Enable checking for Suspect Parts. Set maximum and

minimum values for Time, Power and/or Energy.

7. Enable checking for Bad Parts. Set maximum and

minimum values for Time, Power and/or Energy.

8. Configure advanced hardware settings including

Phase, Free Run Frequency, Frequency Lock and
Hold, and Frequency limits.

Parameters that can be obtained via PROFIBUS

1. All parameters that are configured via PROFIBUS

2. Real time data which includes welder state (ultrasound

active or not), frequency, power, and amplitude.

3. Weld cycle data from previous weld which includes:

• Cycle Count

• Good, Bad, and Suspect Part information

• Process Limit setting exceeded or not reached if Bad
or Suspect Part checking is enabled

• Weld Time

• Weld Energy (Time and Energy option)

• Peak Power

For information on how to control and/or monitor specific
parameters, iQ Generator PROFIBUS Communication and
Control documentation is available.

Signing a non-disclosure agreement is required to obtain this
documentation.

Figure 10-20

PROFIBUS Communications Module

PROFIBUS

Module

Bus error activates LED (Red)

Advertising