Remote amplitude control module, Iq series, Current loop fault – Dukane ULTRASONIC GENERATOR/POWER SUPPLY LS 403-574-01 User Manual

Page 88: Future availability

Advertising
background image

Page   

iQ Series

,

Ultrasonic Generator/Power Supply LS User’s Manual

Dukane Manual Part No. 403-574-01

Remote Amplitude Control

Module

Part Number - 110- 4183

This optional module enables remote control of output
amplitude of the iQ system. The control interface is a
4–20mA current loop. The current loop connector and
fault indicator are shown below in Figure 10–12. The
output can be adjusted from 36% to 100%. The scale
factor is a 4% amplitude change for each mA change. A
graph of amplitude output as a function of loop current
is shown in Figure 10-11. The current loop compliance
voltage is 6 volts minimum.
Failure to provide at least 4mA of loop current is sensed as
a fault and will produce minimum amplitude output.
The current loop fault indicator is a bi–color LED. It is
green when the current is between 4 and 20mA and red
when the current is below 2mA.

Current Loop Fault

If a current loop source is not available, an external +24VDC
power supply can be connected to the POS and NEG
terminals of J7. (See Figure 10-12.) A +22VDC supply is
also available on System Output Pins 1(+) and 3(-).

5mA

0mA

20%

0%

40%

60%

80%

100%

10mA

15mA

20mA

4mA

Current

Loop

Fault

Region

36%

Figure 10-11

Current Loop Transfer Function Graph

Future Availability

In the future, Remote Power Regulation Control will
become available. This option module will be able to
remotely control the power regulation setpoint using new
user-selection menu choices made from the front panel.

Figure 10-12

Remote Amplitude Control Module

LINE VOLTAGE:
200-240 Vac
50/60Hz, 10A

PE

J1

J4

J3

J2

J7

SYSTEM INPUTS

SYSTEM OUTPUTS

CONFIGURATION

U/S

CURRENT LOOP

INPUT

STATUS

PO

S

NEG

SHI

ELD

E-STOP

Current Loop Fault Indicator - Green/Red LED

Current Loop Connector

Advertising