System Inputs Signal Descriptions

Pin 1 (+22V)

This pin can supply +22VDC at up to 250mA to power
the user’s automation controls.

Pin 2 (Power Gnd)

Pin 2 is the 22VDC return and is tied to the system chas-
sis ground.

Pin 3 (Remote Setup Selection Bit 0 Input)

Pin 3 is the Remote Setup Selection Bit 0, which is the
least significant bit used to select different welding set-
ups with an automation control system. This input is also
used to select different channels when a Multiple Probe
Controller (MPC) Interface option board is installed.

Pin 4 (Remote Setup Selection Bit 1 Input)

Pin 4 is the Remote Setup Selection Bit 1, which is the
second least significant bit used to select different weld-
ing setups with an automation control system. This input
is also used to select different channels when a Multiple
Probe Controller (MPC) Interface option board is in-
stalled.

Pin

Signal Name

Cable Color Code

Signal Option Requirements

1

+22V

BLK

2

Power Ground

WHT

3

Remote Setup Selection Bit 0 Input

RED

MPC Option Required

4

Remote Setup Selection Bit 1 Input

GRN

MPC Option Required

5

Remote Setup Selection Bit 2 Input

ORN

MPC Option Required

6

Remote Setup Selection Bit 3 Input

BLU

MPC Option Required

7

Remote Setup Selection Bit 4 Input

WHT/BLK

Not Used

8

Ultrasound Activation/Cycle Start Input

RED/BLK

9

Automation Thruster Control Input

GRN/BLK

Automation Thruster Board Required

10

Front Panel Control Lock Input

ORN/BLK

11

Press Inhibit for Hand Probes

BLU/BLK

Hand Probe

12

System Latch Reset Input

BLK/WHT

13

Isolated Common

RED/WHT

14

Not Used

GRN/WHT

15

Automation Cycle Stop Input

BLU/WHT

Figure 4 - 4

HD-15F, Generator Input Connector

Figure 4 - 5

HD-15M, Generator Input Cable

Connector

1 2 3 4 5

6

10

11 12 13 14 15

5 4 3 2 1

5 4 3 2 1

15 14 13 12 11

15 14 13 12 11

6

6

10

10

Table 4 - I System Input Connector Signals (J2)