Start-up sequence – Dukane ULTRASONIC GENERATOR/POWER SUPPLY LS 403-574-01 User Manual

Page 46

Advertising
background image

Page  40 

iQ Series

,

Ultrasonic Generator/Power Supply LS User’s Manual

Dukane Manual Part No. 403-574-01

Start-up Sequence

After all connections have been completed,

1. Push the rear panel AC breaker switch to ON.

The generator begins its self-diagnostics sequence.

2. POWER TEST flashes (RED) for several seconds.

3. First, the entire System Power Output Level bargraph

lights up momentarily (verifying that all bar graph

LED

segments are functional). Next, two short “beeps” are
sounded as the OVERLOAD

LED

flashes.

4. The System Operating Mode shifts to either ONLINE or

OFFLINE depending on what was previously selected.
See System Operating Mode on Page 31.

5. The LCD display identifies the Dukane iQ Series type

first. Then another screen provides system detail.

See the Start-up (1 and 2) Figures 5-3 and 5-4 to the
right.

6. When the diagnostics sequence is finished, the next

screen to appear will look like Figure 5-5.

This is the Process Data screen, and that is linked to
the OPERATE MODE menu.

This screen is updated after each weld cycle.

7. Press CANCEL twice and you will be at the Main Menu

as shown at right.

LOAD

80

60

100

OVER

40

0

20

SYSTEM POWER OUTPUT LEVEL

SYSTEM OPERATING MODE

POWER

TEST

# 1 PART COUNT 125
WELD TIME 0.080 S
POWER 1050 W
ENERGY 350 J

Figure 5 - 5 LCD Display at Start-up 3

Figure 5 - 6 Main Menu

# 1:
OPERATE MODE
PROCESS SETUP
HARDWARE SETUP

NOTE

A welding cycle cannot be started when the
mode is OFFLINE because this blocks the
ultrasound activation signal input.

# 1 PART COUNT 0
WELD TIME 0.0000 S
PEAK POWER 0 W
ENERGY 0 J

Figure 5 - 4 LCD Display at Start-up 2


AUTOMATED PROBE


TIME + ENERGY
20kHz 2400 W SYSTEM

Figure 5 - 3 LCD Display at Start-up 1

DUKANE iQ LS SERIES