Dukane ULTRASONIC GENERATOR/POWER SUPPLY LS 403-574-01 User Manual

Page 49

Advertising
background image

Page  43

Section 6 – Process Control Settings

Dukane Manual Part No. 403-574-01

Continued

Setting Description

User Adjustment Limit

Setting Ranges for All Frequencies

Minimum

Maximum

Amplitude Setting

20%

100%

Free Run Frequency ***

Default Free Run
Frequency minus 500 Hz

Default Free Run
Frequency plus 500 Hz

Ramp-up Time

0.010 second

1.250 second

Phase Delay

Default Phase Delay
minus 20º

Default Phase Delay plus
20º

Table 5 - III System Parameter Adjustment Limits

*** NOTE: Free Run Frequency for 15kHz generators,
Minimum = Default Free Run Frequency minus 600 Hz;
Maximum = Default Free Run Frequency plus 600 Hz.

System Parameter Adjustment Limits

Continued from previous page

Advertising