Datalogic Scanning DS6300 User Manual

Page 18

Advertising
background image

DS6300

1

The mirror can be deflected up to 40°. Oscillation with respect to the output window median
axis is asymmetrical ( see figure below).

40°

37

.5

°

-2.

Figure 3 - Oscillating Mi

rture and Asymmetry


By configuring the oscillating speed up to the maximum value of 19 Hz, raster emulation can
be performed for read

st moving objects

Max.

ture

rror Maximum Ape

ing fa

.

Hz

Aper

0-5 40°

6-10 30°

11-15 20°
16-19 10°


NOTE

By limiting the raster width to the minimum necessary, the number of
scans on the reading surface is increased.


Oscillating angles are selected in software where the minimum and maximum angles
correspond to –2.5° and +37.5°.

The scanner can be tilted in order for the 17.5° software setting to correspond with the 0°
horizontal plane.

4

+17.5°

+37.5°

-2.5°

Figure 4 - Oscillating Mirror Extreme Angle Positions


These models provide higher scanning speed (1200 scans/sec) compared to standard
models and the reading performance is not adversely effected by the oscillating mirror.

Advertising