Datalogic Scanning DS6300 User Manual

Page 66

Advertising
background image

DS6300

2

Display Visualization

The first line of the display shows the read code and Good Read percentage. Possible
suspending commas at the end of the code mean that the code is too long to be
displayed.
The second line of the display indicates the value of the focus position according to the
table below. The indications “Too Near” or “Too Far” are represented for values outside
the focus range.

Graphical Visualization

Numerical Visualization

A

|---^----------|

Æ

where ^ indicates the focus position

Fxxx

Æ

where xxx ranges from 000 to 100

B

N-------------|

Æ

where N indicates that the focus

position is “Too Near”

TooNear

C

|--------------F

Æ

where F indicates that the focus

position is “Too Far”

Fxxx*

Æ

where xxx is greater than 100

CodeRead… 100%
|------^------------------|

CodeRead… 094%
F034

Figure 63 – Graphical Visualization

Figure 64 – Normal Visualization

5) Rotate the focus adjustment screw to reach the desired focus position. The display is

refreshed with the new values;

1

6) Press the ▲ (up arrow) key to exit the Test Mode;

7) Use the ▲ (up arrow) and ▼ (down arrow) key to select the “Exit” item, then press the

ENT (enter) key to confirm. The scanner exits the Main Menu and returns to its current
operating mode.


Figure 65 - Focus Adjustment Screw


NOTE

The reader display shows the focus position only when the laser beam is
activated.


It is possible to visualize the focus position and the reading percentage on the terminal tool
provided by the Genius™ configuration program (see Genius™ Help On-Line for details).

1

To avoid breakage, do not use excessive force when rotating the focus adjustment screw.