Alternative slave address assignment, Advanced genius™ configuration, Par. 3.2.3 – Datalogic Scanning DS6300 User Manual

Page 75

Advertising
background image

SOFTWARE CONFIGURATION

3

3.2.3 Alternative

Slave Address Assignment


As alternatives to Network Setup through the Master, each Slave scanner can be assigned
an address through the following methods:

address setting through the Local Device Network Settings item in the Device Menu

with the slave scanner connected to Genius™

• manual address setting through slave scanner keyboard (see par. 2.8.1 for

details).


3.3 ADVANCED GENIUS™ CONFIGURATION


The ADVANCED selection available when starting the Genius™ program is addressed to
expert users being able to complete a detailed scanner configuration. By choosing this option
it is possible either to start a new scanner configuration or to open and modify an old one.
The desired parameters can be defined in the following window, similar to the MS Explorer:

Figure 73 - Genius™ Parameter Explorer Window


The procedure for setting the scanner parameters is supported by an help on-line, which is
displayed in an HTML browser. It can be selected from the Configuration Help option
available in the Help menu. In addition, a context-sensitive help can be enabled by pressing
the <F1> key after selecting the desired parameter.

61

Advertising