Main/aux. serial interface and i/o connector, 1 main/aux. serial interface and i/o connector – Datalogic Scanning DS6300 User Manual

Page 31

Advertising
background image

INSTALLATION

2

2.3.1 Main/Aux. Serial Interface and I/O Connector


The DS6300 master/slave model is equipped with a 25-pin male D-sub connector for
connection to the host computer, power supply and input/output signals.

The DS6300 fieldbus models (Ethernet, DeviceNet, Profibus) adopt a 26-pin male connector
instead of the 25-pin one.

The details of the connector pins are indicated in the following table:

10

19

1

18

9

26

14

1

25

13

Figure 17 - 26-pin Connector

Figure 18 - 25-pin Connector


DS6300 25-pin/26-pin D-sub connector pinout

Pin Name

Function
Chassis - internally connected to GND

1 CHASSIS

Cable shield connected to chassis

20

RXAUX

Receive data of auxiliary RS232 (referred to GND)

21

TXAUX

Transmit data of auxiliary RS232 (referred to GND)

8

OUT 1+

Configurable digital output 1 - positive pin

22

OUT 1-

Configurable digital output 1 - negative pin

11

OUT 2+

Configurable digital output 2 - positive pin

12

OUT 2-

Configurable digital output 2 - negative pin

16

OUT 3A

Configurable digital output 3 - polarity insensitive

17

OUT 3B

Configurable digital output 3 - polarity insensitive

18

EXT_TRIG/PS A External trigger (polarity insensitive) for PS

19

EXT_TRIG/PS B External trigger (polarity insensitive) for PS

6

IN 2/ENC A

Input signal 2 (polarity insensitive) for Encoder

10

IN 2/ENC B

Input signal 2 (polarity insensitive) for Encoder

14

IN 3A

Input signal 3 (polarity insensitive)

15

IN 4A

Input signal 4 (polarity insensitive)

24

IN_REF

Common reference of IN3 and IN4 (polarity insensitive)

9,13

VS

Supply voltage - positive pin

23,25,26 GND

Supply voltage - negative pin

Main Interface Connector Pinout

Pin

RS232

RS485

Full Duplex

RS485

Half Duplex

20 mA C.L.

(INT-30 with C-BOX 100 only)

2

TX

TX485 +

RTX485 +

see INT-30 instructions

3

RX

* RX485 +

4

RTS

TX485 -

RTX485 -

5

CTS

* RX485 -

7 GND_ISO GND_ISO

GND_ISO


Pin 26 is only available for fieldbus models (Ethernet, DeviceNet, Profibus).

* Do not leave floating, see par. "RS485 Full-Duplex Interface" for connection details.

17