Installation – Datalogic Scanning DS6300 User Manual

Page 37

Advertising
background image

INSTALLATION

2

EXTERNAL TRIGGER/ENCODER

DS6300

A/B

Vext

B/A

V

+ 5V

~

~

+

-

Ground

Figure 26 - NPN Command Input Connection using External Power



EXTERNAL TRIGGER/ENCODER

DS6300

A/B

B/A

GND

V

+ 5V

~

~

+

-

Ground

VS

Figure 27 - NPN Command Input Connection using Scanner Power



EXTERNAL DEVICE

DS6300

IN3A

Vext

Ground

V

+ 5V

~

~

+

-

Ground

V

IN4A

+ 5V

~

~

+

-

INREF

Vext

Figure 28 - IN3/IN4 PNP Input Command using External Power

23

Advertising