4

DS6300-105-0XX (oscillating mirror) - Resolution: 0.38 mm/15 mils


4

2

0

6

(in)

0 10

16

(in)

12 14

18 20

0 25 30 35

40 45 50

(cm)

25

20

15

10

0

(cm)

5

-5

-10

-15

-20

-25

8

10

-8

-10

-6

-4

-2

55

60

24

22

26 28

Focus

Position = 0

-30

-12

30

12

65 70

75

80

32

30

34

36

Focus

Position = 60

85

90 95 100

105

35

40

-35

-40

Focus

Position = 100

38 40 42

14

16

-14

-16

Figure 84 - Oscillating Mirror Model 0.38 mm / 15 mils Reading Diagram

CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
Pitch angle = 0°
Skew angle = 10° - 20°
Tilt angle = 0°

Note:

(0,0) is the center of the laser beam output window.