Datalogic Scanning DS6300 User Manual

Page 85

Advertising
background image

READING FEATURES

4

DS6300-100-0XX - Resolution: 0.50 mm/20 mils


8

4

0

12

(in)

0 8

20

(in)

12 16

24

28

0 20 30 40 50 60

70

80

90

(cm)

50

40

30

20

0

(cm)

10

-10

-20

-30

-40

-50

16

20

-16

-20

-12

-8

-4

100

36

32

40

44

Focus

Position = 60

-60

-24

60

24

48 52 56

Focus

Position = 100

110 120 130 140

Focus

Position = 0

150

Figure 81 - Standard Model 0.50 mm / 20 mils Reading Diagram

CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
Pitch angle = 0°
Skew angle = 10° - 20°
Tilt angle = 0°

Note:

(0,0) is the center of the laser beam output window.

71

Advertising