Datalogic Scanning DS6300 User Manual

Page 78

Advertising
background image

DS6300

3

Parameter

Default Setting

Auxiliary Serial Port

Heartbeat Disable
Pass Through

Disabled (unchecked)

Parameters
Baud

Rate

115200

Parity

None

Data

Bits

8

Stop

Bits

1

Digital I/O Setting

Digital Input Lines Setting

Debouncing For Input 1, 3 and 4

5 ms

Debouncing For Input 2

500 µs

Input 1 Active Level Overridden by Op. Mode Active Closed
Input 2 Active Level Overridden by Op. Mode Active Closed
Input 3 Active Level Overridden by Op. Mode Active Closed
Input 4 Active Level Overridden by Op. Mode Active Closed
Output 1

Line State

Normally Open

Activation Event

Complete Read

Alternative Activation Event

Wrong

Deactivation Event

Timeout

Alternative Deactivation Event

None

Deactivation Timeout (ms)

50

Output 2

Line State

Normally Open

Activation Event

No Read

Alternative Activation Event

Partial Read

Deactivation Event

Timeout

Alternative Deactivation Event

None

Deactivation Timeout (ms)

50

Output 3

Line State

Normally Open

Activation Event

None

Alternative Activation Event

None

Deactivation Event

None

Alternative Deactivation Event

None

System Information Section

User Information Section

End User Name

Device Name

Line Name

Diagnostics

PackTrack Debug Message TX

Disabled (unchecked)

Enable Unchecked
Statistics

Disabled (unchecked)

64

Advertising