CUSTOM AT COMMANDS
HSPA+ AT Commands Reference Guide
208
<mode>
0
Disable the single event monitoring. Default: 0.
1
Enable the single event monitoring.
<paramType>
Numeric parameter indicating the type of parameter contained in <param>.
0 value indicates that <param> contains the AT command string to execute when
the related event has occurred. Other values depend from the type of event.
<param>
Numeric or string value depending on the value of <paramType> and on the type
of event.
If <paramType> is 0, then <param> is a string containing the AT command:
It has to be enclosed between double quotes
It has to start with the 2 characters AT (or at).
If the string contains the character ”, then it has to be replaced with the 3 characters \22.
The maximumstring length is 96 characters.
If it is an empty string, the AT command is erased.
If <label> is VBATT, <paramType> can assume values in the range 0 ‐ 2.
if <paramType> = 1, <param> indicates the battery voltage threshold in the range 0 – 500, where one unit
corresponds to 10 mV (therefore 500 corresponds to 5 V). Default: 0.
if <paramType> = 2, <param> indicates the time interval in seconds after that the voltage battery under the
value specified with <paramType> = 1 causes the event. The range is 0 – 255. Default: 0.
If <label> is DTR, <paramType> can assume values in the range 0 ‐ 2.
if <paramType> = 1, <param> indicates the status high or low under monitoring. The values are 0 (low) and 1
(high). Default: 0.
if <paramType> = 2, <param> indicates the time interval in seconds after that the DTR in the status specified
with <paramType> = 1 causes the event. The range is 0 – 255. Default: 0
If <label> is ROAM, <paramType> can assume only the value 0. The event under monitoring is the roaming state.
If <label> is CONTDEACT, <paramType> can assume only the value 0. The event under monitoring is the context
deactivation.
If <label> is RING, <paramType> can assume values in the range 0 ‐ 1.
If <paramType> = 1, <param> indicates the numbers of call rings after that the event occurs. The range is 1‐
50. Default: 1.
If <label> is STARTUP, <paramType> can assume only the value 0. The event under monitoring is the module
start‐up.
If <label> is REGISTERED, <paramType> can assume only the value 0. The event under monitoring is the network
registration (to home network or in roaming) after the start‐up and the SMS ordering.
If <label> is GPIOX, <paramType> can assume values in the range 0 ‐ 3.
if <paramType> = 1, <param> indicates the GPIO pin number; supported range is from 1 to a value that
depends on the hardware. Default: 1.
if <paramType> = 2, <param> indicates the status high or low under monitoring. The values are 0 (low) and 1
(high). Default: 0.
if <paramType> = 3, <param> indicates the time interval in seconds after that the selected GPIO pin in the
status specified with <paramType> = 1 causes the event. The range is 0 – 255. Default: 0.
If <label> is ADCH1, <paramType> can assume values in the range 0 ‐ 3.